Monitoring
Combined opening and locking monitoring system
Detects and reports every security risk.
AEROCONTROL magnetic switches, depending on the version, can not only
check whether the sash is fitted into the frame and whether it is properly
locked, it can do both simultaneously. With this combined opening and locking
monitoring system, not only is the opening of the sash detected, but also the
activation of the handle as well as any attempt to shift the locking cam of the
hardware by force. To do this, a hardware component with a magnetic cam
is used, which will only close a contact in the magnetic switch that in turn is
connected to the burglar-resistance system, when the fitting is in the correct
closing and locking position. If the contact is interrupted, the magnetic switch
notifies the central monitoring unit of this without delay, which can trigger an
alarm or notify a security company for example.
Window securely locked:
contact between magnetic switch and
mobile cam
Locking monitoring system:
hardware is not properly locked
or shifted using force
Opening monitoring system:
sash not fitted in frame,
contact interrupted
AEROCONTROL magnetic switch
For the highest security demands.
44