AEROCONTROL Product catalogue Intended use • All AEROCONTROL products are tested to make sure they are in perfect working order before they leave our premises. Every instruction in this technical documentation must be observed to avoid any damage and customer complaints resulting from incorrect installation. • Before each work step, please read the associated section of this documentation carefully and thoroughly and comply with the specified sequences. • Only VdS-approved switches may be used in VdS-compliant systems. • The AEROCONTROL may only be assembled and installed by the following persons: Assembly: Window fitter Installation: In the case of VdS-approved systems, installation must be carried out by a certified alarm system installation company. • For fume extraction hood control purposes, only DIBt-approved safety extraction switches may be used in Germany. Cable extension in the case of VdS-compliant systems • When replacing a defective magnetic switch, disconnecting or modifying the existing line (e.g. patching on or soldering) is not allowed. The magnetic switch, including its cable, must then be completely replaced. The cable is a component of the assembly tested according to VdS guidelines. This assembly may not be modified at a later point. VdS classification and approval The VdS guideline for intruder alarm systems, no. VdS 2311, states: "Intruder alarms must be selected taking the respective monitoring tasks and the ambient conditions into account and observing the installation instructions of the system proprietor/manufacturer". The magnetic switches are subject to special requirements with regard to tamper protection and monitoring. They are usually equipped with an anti-tamper line. This is also why the wires all have the same colour (white). The classes are easily distinguished as follows: Class A: No or only little tamper protection. Usually no anti-tamper line. Class B: Higher requirements to prevent tampering. Anti-tamper lines present. Class C: High requirements to prevent tampering (e.g. external magnetic fields). Anti-tamper lines present Only use SIEGENIA components; otherwise, VdS approval will not apply. Positioning the magnetic switches The positioning depends on the existing hardware components and the window design and is to be done according to the relevant hardware overviews. The system is only VdS-compliant when the alarm signal is not suppressed by an additional magnetic switch (e.g. monitoring of a tilted window). In accordance with the VdS guideline: "Opening warning devices must be arranged on windows and doors so that every intended opening type leads to an alarm. Mounting should be carried out in the middle at the top, if possible, but a maximum of 60 cm away from the opening side. In the case of multi-sash doors/gates and windows, there must be at least one opening warning device mounted on each sash." 8 Last update: 07.2014


aerocontrol_pk_h4006_2257_en
To see the actual publication please follow the link above