Installation and mounting instructions

aerocontrol_pk_h4006_2257_en

Product catalogue AEROCONTROL Installation and mounting instructions Possible sources of error • Cable kinking (no protective hose) • Connection voltage and currents too high • Externally acting forces (shocks, impacts, do not use hammer) • Switching distance/installation situation (airgap/cavity too large) • Inductive and capacitive overload (e.g. relay, unsuitable measuring devices) • Heat (temperature range > 75 °C) • Magnetic field change in the case of steel • Ferromagnetic materials such as reinforcement change the switching distance. • Non-magnetic fixing screws are not used. To ensure that the magnetic switch can be replaced and to prevent any potential complaints (e.g. cable separation or cable kinking), the protective hose from the accessories range should be used when mounting. Positioning the magnetic switch and magnetic cam Offsetting the magnetic cam on the magnetic switch Hardware travel for calculating offset in turning position Offset X = travel + Y Magnetic switch distance in locking position Magnetic switch Dimension Y UMS124 12 mm +2 UMS1080 9 mm +2 Hardware range Travel FAVORIT 16 mm TITAN iP 18 mm TITAN AF 18 mm Magnetic switch Sash rebate edge 4 mm +1 Centre Eurogroove Y X Travel Last update: 07.2014 37