UMS003

aerocontrol_pk_h4006_2257_en

Product catalogue AEROCONTROL Magnetic switch type UMS003 - 6-pin with external magnetic field monitoring Technical data b1 B A b2 a2 a1 c2 c1 a1-a2 Contact type: N/O contact b1-b2 Contact type: N/C contact (external magnetic field contact) Cannot be used for tilt monitoring Description Material number Colour Cable length VPE Magnetic switch UMS003 VdS-UEBW.6P. 899564 White 6 m 1 315149 White 6 m 25 899571 Silver 6 m 1 315156 Silver 6 m 25 315194 White 10 m 25 Technical data N/O contact for locking monitoring N/C contact, external magnetic field contact Working contacts A B Casing material ABS Cable LIYY 6 x 0.14 mm2 ZGL Contact load 10 W 3 W Max. DC switching voltage 100 V DC 30 V DC Max. DC switching current 0.5 A 0.2 A Min. insulation resistance 109 ohms Contact resistance at 10 AW overvolting 0.1 ohms 0.15 ohms Temperature with permanently installed cable -25 °C to 70 °C Temperature with loose cable -5 °C to + 50 °C Environmental class according to VdS 2110 3 Protection class according to DIN 40050, waterproof IP 68 Combined locking and status monitoring VdS approval no. Class C: G 102063 Minimum values for N/O and N/C contacts are 0.05 mA (current) and 1 V DC (voltage) Note: All cable wires are the same colour in order to safeguard against tampering. Observe the notes on potential sources of error; see page 25. Last update: 07.2014 21