A+
1254/2014
SIEGENIA AEROTUBE WRG smart
A+
A
B
C
D
E
F
G
46 45
dB
m³/h
ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI
H45.WANS007INT/1
2016
500 mm
Ø 160 mm
63 mm
□ 279 mm
1 2 3 4 5 6
Technical specifications
AEROTUBE WRG smart
Air throughput (active)
with blower level 1
with blower level 2
with blower level 3
approx. 15 m³/h
approx. 32 m³/h
approx. 45 m³/h
Inherent noise 1)
with blower level 1
with blower level 2
with blower level 3
LPA = 25 dB(A)
LPA = 38 dB(A)
LPA = 46 dB(A)
Sound absorption Dn,e,w
2) 35 dB
Heat recovery efficiency max. 90 %
Technical approval Z-51.3-387
1) Measured in accordance with DIN EN ISO 3745 with room insulation 8 dB
2) Measured in accordance with DIN EN 10140-2
1) Ventilation pipe
2) Heat accumulator stone
3) Filter G3
4) Axial ventilator
5) Pipe inset
6) Casing with slider and front panel
Weather grille stainless steel or PVC Stainless steel weather protection hood
Installation options with vent duct
Vent duct EPP, type FL Vent duct EPP, type SFL: