Volume flow m³/h1)
12
10
8
6
4
2
0
0 10 20 30 40 50 60 70 80 90 100
14
Flow control due to
aerodynamics
Pressure differential in Pa
30
20
10
0
Flow control due to control
flap
Flow control due to
aerodynamics
0 100 200 300 400 500 600
Volume flow m³/h1)
Pressure differential in Pa
Maximum performance data of the AEROMAT mini without
influence of the window
Sound absorption in accordance with ISO 140-10:1991-12
Test results: given that the window has a sound absorption of 42
dB, the use of one AEROMAT mini reduces sound absorption by
1 to 2 dB and the use of two AEROMAT mini units reduces sound
absorption by 3 dB. The turn lock has no effect on the sound ab-sorption.
Performance data of the AEROMAT mini in the window
Example: PVC window, medium sealing system, RAM: 1,230 x
1,480 mm Volume flow of the AEROMAT mini as independently
regulating passive air ventilator (ALD) with upper flow control.
Technical specifications
Volumetric flow limiter
AEROMAT mini
Amount of air (approx.) at
2 Pa
4 Pa
5 Pa
7 Pa
8 Pa
10 Pa
20 Pa
up to
2 m³/h1)
3 m³/h1)
3 m³/h1)
5 m³/h1)
5 m³/h1)
6 m³/h1)
11 m³/h1)
Dimensions without turn lock (W x H x D) 125 mm x 21.3 mm x 16.4 mm
Dimensions with turn lock (W x H x D) 125 mm x 18 mm x 22.5 mm
1) when installed in pairs independently of profile and hardware
Optional turn lock
31